OPEN HOLE CAPACITY (m3/100m)

Hole Diameter (mm)2

12732


ANNULAR VOLUME (m3/100m)

= Hole Diameter (mm)2 - Pipe Diameter (mm)2

  12732


RECTANGULAR TANK VOLUME (m3)

= Length (m) X Width (m) X Height (m)


CYLINDRICAL TANK VOLUME (m3)

= Tank Diameter (m)2 X Height (m)

   1.2733


HYDROSTATIC PRESSURE (kPa)

= Mud Density (kg/m3) X Depth (m) X 0.00981


FORMATION PRESSURE (kPa)

= SIDPP (kPa) + Hydrostatic Pressure (kPa)


BARITE (kg) REQUIRED TO RAISE DENSITY 1 TO DENSITY 2

= 4200 X (D2 – D1) X Mud Volume (m3)

    4200 – D2


VOLUME (m3) OF WATER REQUIRED TO REDUCE DENSITY 1 TO DENSITY 2

= (D1 – D2) X Mud Volume (m3)

    D2 – 1000


VOLUME (m3) INCREASE DUE TO WEIGHTING MATERIAL

= Amount of Weighting Material Added (kg)

   Weighting Material Density (kg/m3)


TOTAL CIRCULATING TIME (min)

= Total Circulating Volume (m3)    

   Pump Output (m3/min)


BOTTOMS UP TIME (min)

= Total Annular Volume (m3)

    Pump Output (m3/min)


ANNULAR VELOCITY (m/min)

= Pump Output (m3/min) X 1273 x 103

    Hole Diameter (mm)2 – Pipe Diameter (mm)2